48
Other Hardware Errors
CD-ROM drive LED does not light
Reason
CD-ROM drive power cable is not attached.
Floppy disk drive/combo drive LEDs do not light
Reason
Disk drive power cable is not attached.
Floppy disk drive/combo drive not recognized
Reason
BIOS is not configured properly.
Disk drive power cable is not attached.
Floppy data cable is not attached properly.
Unsuccessful connection to serial device
Reason
Communication parameters between server
and serial device do not match.
Solution
Open the base unit and ensure power cable
is properly attached.
Solution
Open the base unit and ensure power cable
is properly attached.
Solution
Configure the Floppy A and B parameters
under Standard to the required settings.
Open the base unit and ensure the power
cable is properly attached.
Open the base unit and ensure the floppy
cable is properly attached at both ends.
Solution
Change the parameters so the server and
serial device match each other.