Table 5-2 Storm Water Runoff Sampling (Continued)
ENABLE:
RAIN LEVEL FLOW
35
NONE
ENABLE: RAIN
36
AND
OR
DONE
ENABLE: RAIN AND
LEVEL FLOW NONE
37
"RAIN" SET POINT:
0.15 INCHES PER
38
__HOURS, __MINUTES
ENABLED WHEN:
ABOVE SET POINT
39
BELOW SET POINT
RESET RAIN HISTORY?
40
YES
NO
"LEVEL" CONDITION:
SET POINT
41
RANGE
RATE OF CHANGE
"LEVEL" SET POINT
0.25 ft
42
(0.001-30.000)
ENABLED WHEN:
ABOVE SET POINT
43
BELOW SET POINT
ONCE ENABLED,
STAY ENABLED?
44
YES NO
SAMPLE AT ENABLE?
45
YES NO
PAUSE RESUME
1. HH:MM DD
HH:MM DD
46
2. HH:MM DD
HH:MM DD
CLEAR DONE
UNIFORM TIME PACED
FLOW PACED
47
EVENT PACED
NONUNIFORM TIME
Select RAIN.
Note: All valid enable options will appear here, so your screen may differ.
Select AND.
Select LEVEL.
Enter 0.15 for inches, then enter 30 minutes.
Select ABOVE SET POINT.
Select YES.
Select SET POINT.
Enter 0.25.
Select ABOVE SET POINT.
Select YES.
Select YES.
Select DONE.
Screen will say "End of Part A" then "Beginning Part B."
Select FLOW PACED.