Section 5 Extended Programming
6712 SAMPLER
EXTENDED PROGRAMMING
1
For HELP at any
screen press ? key.
RUN "EXTENDED 1"
PROGRAM
2
VIEW REPORT
OTHER FUNCTIONS
PROGRAM NAME:
"EXTENDED 1 "
3
CHANGE?
YES NO
SELECT NEW PROGRAM
4
CHANGE PROGRAM NAME
NAME: "STORM
ABCDEFGHIJKLMNOPQRST
5
UVWXYZ-& 0123456789
BACK-UP DONE
SITE: DESCRIPTION
"FACTORY051"
6
CHANGE?
YES
NO
SITE: "SITE 54 "
ABCDEFGHIJKLMNOPQRST
7
UVWXYZ-& 0123456789
BACK-UP DONE
SELECT UNITS FOR
8
LENGTH:
ft
m
SELECT UNITS FOR
FLOW RATE
9
cfs gps gpm Mgd
lps m3s m3h m3d
SELECT UNITS FOR
FLOW VOLUME
10
cf gal Mgal
m3
lit
5-6
once enabled, stay enabled, no sample taken when the
sampler is enabled; first sample taken 20 minutes after
the sampler is enabled.
• Part 'B' pause and resumes: None.
• Start time: Delayed start of 1 minute.
• 730 Bubbler Module: Installed
Table 5-2 Storm Water Runoff Sampling
This screen will appear briefly.
Select PROGRAM.
Note: If the start-up screen displayed "STANDARD PROGRAMMING", type
6712.2 at this menu before selecting PROGRAM.
Select YES.
Note: If the quick view screen shows up, press STOP then select OTHER
FUNCTIONS, SOFTWARE OPTIONS, QUICKVIEW/CHANGE, NORMAL.
Then press STOP and go back to step 2.
Select CHANGE PROGRAM NAME.
"
Enter the word "STORM" for the program name.
Select YES.
Enter "SITE 54" for the site description.
Select ft.
Select gpm.
Select gal.