7-14. Flare Adjustment

Preparation
. On the setup menu, set as follows.
PAGE
: S24*LEVEL 7
ITEM
: TEST OUT
. OUTPUT/DCC switch (inside panel)
. Shoot a grayscale chart (16:9) in the full underscanned
monitor frame.
Equipment
: Waveform monitor
Test point
: TEST OUT connector
: 1 Lens IRIS
Setting point
Spec.
: Open the lens iris by one step from the
reference setting
A = 100 ±2 IRE (NTSC)
A = 700 ±14 mV (PAL)
Adjustment Procedure
Equipment
: Waveform monitor
Test point
: TEST OUT connector
1. Select the 16:9 mode.
PAGE
: S14*WIDE SCREEN
ITEM
: 16:9/4:3 MODE
2. On the setup menu, set as follows.
PAGE
: S24*LEVEL 7
ITEM
: G FLARE
3. Select portion B by using the waveform monitor.
DVW-790WS/709WS/707
DVW-790WSP/709WSP/707P P2V1
16:9 mode
ENC
CAM/ON
A
16:9
0
B
4. On the setup menu, adjust as follows.
PAGE
: S24*LEVEL 7
ITEM
: R FLARE
Spec.
: Minimize the carrier leakage at portion C
5. On the setup menu, adjust as follows.
PAGE
: S24*LEVEL 7
ITEM
: B FLARE
Spec.
: Minimize the carrier leakage at portion C.
6. Repeat steps 4 and 5 several times.
7-14. Flare Adjustment
C
7-19