PLC-XC50/55 Expand Serial Command Functional Specifications
8.10.4
CF_AUTOSETUP Command
Command
"CF_AUTOSETUPPCADJ_%1"[CR]
%1
"START" ------------------- Execute Auto Setup
Execute Auto Setup
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.5
CF_INPUTSEARCH Command
Command
"CF_INPUTSEARCH_%1"[CR]
"OFF" ------------------------- Set Input search operation to OFF
%1
"ON1" ------------------------- Set Input search operation to On1
"ON2" ------------------------- Set Input search operation to On2
Set Input search operation mode.
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
Details
This command is available in normal Power ON status.
Note) Keystone, PC adj. and Input search cannot be set "Off" at the same time.
When Keystone and PC adj. are Off, projector returns error code "101" by
receiving this command.
Acceptable
Response
Unacceptable
8.10.6 CF_BBACK Command
Command
"CF_BBACK_%1"[CR]
"ON" ----------------------------- Select Blue Back
"OFF" ---------------------------- Cancel Blue Back
%1
"UP" ------------------------------ Switch setting (On -- Off – On...)
"DN" ------------------------------ Switch setting (On -- Off -- On...)
Note) "UP" and "DN" behave the same.
Set / Cancel Blue Back
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.10.7 CF_DISP Command
Command
"CF_DISP_%1"[CR]
"ON" ----------------------------- Select Display
"OFF" --------------------------- Cancel Display
"CNTDWNOFF" -------------- Count down OFF
"UP" --------------- Switch Display mode in forward direction
%1
"DN" --------------- Switch Display mode in backward direction
Set / Cancel Display
The value set by this command is stored in EEPROM and its setting is effective
Details
even after ALL is OFF.
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
ÿ On -- Count down OFF – Off -- On ... ÿ
ÿ On -- Off -- Count down OFF – On...ÿ
"000"[CR]
"Error Code"[CR]