Cf_Keystone Command; Cf_Kystnmode Command; Cf_Vscale Command - Sanyo PLC-WU3800 Manual

Xpand serial command functional specifications
Hide thumbs Also See for PLC-WU3800:
Table of Contents

Advertisement

PLC-WU3800 Expand Serial Command Functional Specifications
8.7.3

CF_KEYSTONE Command

Command
"CF_KEYSTONE_%1"[CR]
"UP" ------------- Correct Keystone distortion to reduce upper part of image
"FUP" ----------- Correct Keystone distortion to reduce upper part by 2steps
%1
"DN" ------------- Correct Keystone distortion to reduce lower part of image
"FDN" ----------- Correct Keystone distortion to reduce lower part by 2steps
"RST" ------------ Reset Keystone correction
Change Keystone distortion correction
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.7.4

CF_KYSTNMODE Command

Command
"CF_KYSTNMODE_%1"[CR]
"STR" --------- Set Keystone store mode to Store
%1
"RST" --------- Set Keystone store mode to Reset
Set Keystone store mode
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
8.7.5

CF_VSCALE Command

Command
"CF_VSCALE_%1"[CR]
"032" --------- +32
"031" --------- +31
"002" --------- +2
"001" --------- +1
"000" --------- +0
%1
"-01" ---------- -1
"-02" ---------- -2
"-31" ---------- -31
"-32" ---------- -32
"UP" ---------- Vertical Scale setting value + 1
"DN" ---------- Vertical Scale setting value - 1
Set Vertical Scale
This command is available in normal Power ON status.
Details
Note1) Screen mode is changed into Custom by receiving this command.
Note2) When there is no Input, projector returns 101 and the command does not
execute.
Acceptable
Response
Unacceptable
"000"[CR]
"Error Code"[CR]
"201" [CR] ----When reaching the Keystone correction limit or
"000"[CR]
"Error Code"[CR]
ÿ
ÿ
"000"[CR]
"Error Code"[CR]
31/74
reaching 1 step to correction limit and "FDN"/"FUP"
is received.
(The command is not executed)

Advertisement

Table of Contents
loading