Maintenance/replacement

■ Lamp unit

The lamp unit is a consumable component. Check the lamp usage duration with "[Information] menu"
(
page 85) and perform regular replacement.
If the replacement message
REPLACE>/<LAMP 2 REPLACE> turn on, replace the lamp units.
It is recommended that you request a qualified technician to replace the lamp unit. Consult your dealer.
Consult your dealer to purchase the part ET-LAE12 (serviceable part).
Attention
z Do not replace the lamp unit until it has cooled down sufficiently. (Wait at least 60 minutes after use.)
The inside of the cover is very hot and may cause burns.
■ Notes on the replacement of the lamp unit
z Since the luminous lamp is made of glass, it may burst if dropped or hit with a hard object. Please handle
with care.
z A Phillips screwdriver is necessary when replacing the lamp unit.
z When replacing the lamp unit, be sure to hold it by the handle.
z The lamp contains mercury. When disposing of the used lamp unit, ask your nearest local authorities or
dealer about proper disposal of the unit.
Attention
z Use only specified lamp units.
z The product numbers of accessories and separately sold components are subject to change without notice.
z Replacement of all two lamps simultaneously is recommended to ensure a balanced brightness and tint.

■ When to replace the lamp unit

The lamp unit is a consumable component. Replace the lamp unit regularly, as its brightness gradually
decreases over time. The estimated duration before replacement is 2 000 hours (when [Lamp power] is set to
standard). However, this may shorten depending on individual lamp characteristics, usage conditions, and the
installation environment. Earlier replacement of lamp units is recommended for this reason.
The duration exceeds 2 200 hours of usage for one lamp, the lamp will be switched to the other one if it is
available.
If the power is turned on without replacing the lamps after the duration exceeds 2 200 hours of usage for all
lamps, the power automatically turns off after approximately ten minutes to prevent the malfunction of the
projector.
The lamp replacement instructions notify the
replacement time, and the lamp status notifies which
lamp to replace.
96 - ENGLISH
is displayed on the screen and the lamp indicators <LAMP 1
On-screen display
Lamp indicator <LAMP 1 REPLACE>/<LAMP 2
REPLACE>
Turns orange.