Replacement of lamp unit

CAUTION
Wait until the lamp is cooled sufficiently before replacing the lamp unit.
Precautions on lamp unit replacement
Be careful when handling a light source lamp.
The lamp unit has high internal pressure. If
improperly handled, failure might result.
A used lamp unit may burst if it is handled
violently.
For disposition of used lamps, request an
industrial waste disposal contractor.
Do not reset the cumulative time, except when
the lamp unit has been replaced with a new
unit.
If you continue to use a lamp after the
replacement time, the lamp may break.
Philips screwdriver is necessary when replacing
a lamp unit.
Take care not to slip your hand when using a
screwdriver.
Attention
• A lamp unit is an optional part. Contact
the dealer.
Replacement Lamp Unit model No.:
ET-LAD7700 (single bulb),
ET-LAD7700W (double bulbs)
Rating: 300W
Long Life Lamp Unit model No.:
ET-LAD7700L (single bulb),
ET-LAD7700LW (double bulbs)
Rating: 160W
• Other lamps than specified above cannot
be used. Be sure to use the specified
lamp.
100
Timing of lamp unit
replacement
The lamp used for the light source has its due life. The
life of light source lamp used in the main unit is 1 500
hours
(when lamp output is HIGH and lamp
1
selection is DUAL). However, it may happen that the
lamp becomes dead (will not light) by the time of 1 500
hours
depending on the characteristics of individual
1
lamps and working conditions (lamps may reduce their
life affected by the times of lighting and the intervals
between previous lighting and next lighting). Therefore,
it is strongly recommended for the user to keep a
spare bulb.
If your lamp unit is not replaced after 1 300 hours
(with the lamp output set at "HIGH"), power supply will
be turned off automatically at the time of 1 500 hours
entering a standby state. After 1 500 hours
lighting, power supply is turned off automatically about
10 minutes later, entering a standby state even if it is
turned on again.
Indication after 1 300 hours
(with the lamp output set at
"HIGH")
When lamp unit used hours have reached 1 300
hours
2
, lamp monitor (LAMP1 or LAMP2) light
up including standby state.
Further, an on-screen indication will appear for
about 30 seconds as shown in the diagram on the
right, recommending replacement of lamp unit.
(The indication on the below diagram will
disappear after about 30 seconds or when either
control button on the rear of main unit or remote
control button is operated.)
After the time of 1 500 hours
indication will not disappear unless the menu
(MENU) button is operated.
1 This time period is 4 000 hours when Long
Life Lamp Units are used.
2 This time period is 3 800 hours when Long
Life Lamp Units are used.
1
of initial
, the on-screen
1
REPLACE THE LAMP
2
,
1
2