Technical Information
■ Pin assignments and signal names
■
<SERIAL IN> terminal
Outside view
(5)
(9)
(6)
<SERIAL OUT> terminal
Outside view
(1)
(6)
(9)
■ Transmission conditions
■
Signal level
Sync. method
Baud rate
Parity
*1: Fixed to 9 600 bps when [AMX D. D.] is set to on.
■ Basic format
■
Transmission from the computer begins with STX, then the ID, command, parameter, and ETX are sent in this
order. Add parameters according to the details of control.
*1: When sending commands without parameters, a colon (:) is not necessary.
106 - ENGLISH
Pin No.
(1)
(2)
(1)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Pin No.
(1)
(2)
(5)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
RS-232C-compliant
Asynchronous
19 200 bps
*1
None
Signal name
—
NC
TXD
Transmitted data
RXD
Received data
—
NC
GND
Ground
—
NC
CTS
Connected internally
RTS
—
NC
Signal name
—
NC
RXD
Received data
TXD
Transmitted data
—
NC
GND
Ground
—
NC
RTS
Connected internally
CTS
—
NC
Character length
Stop bit
X parameter
S parameter
Details
Details
8 bit
1 bit
None
None