NOTE:
The Alert Sender Domain is probably not required. This box depends on the mail server
setup.
Box
E-mail address
Alert Sender Domain
SMTP Server
1.
Select the Enable AlertMail check box to enable the AlertMail feature.
2.
Enter values for the email address, alert sender domain, and SMTP server.
3.
Click the Apply button to save the settings.
AlertMail, if enabled, sends alerts by email for the following events:
Enclosure status change
Enclosure information change
Fan status change
Fan inserted
Fan removed
Power supply status
Power supply inserted
Power supply removed
Power supply overload
Blade inserted
Blade removed
Blade status
Blade thermal condition
Blade fault
Blade information change
Tray status change
Tray reset
Switch connect
Switch disconnect
All e-mails have the following header:
From: Enclosure ENCLOSURE-NAME <enclosure-name@serverdomain>
Date: Date in standard format
Subject: HP AlertMail-SEQ: <SEVERITY> SUBJECT
To: RECEIVER MAILBOX
Possible value
<account>@<domain>
A character string including all
alphanumeric characters and the dash
(-)
###.###.###.### where ### ranges
from 0 to 255
Description
This box is a valid email address for
the administrator or other designated
individual receiving the AlertMail
The domain in which the Onboard
Administrator resides
An IP address for the SMTP server
Enclosure settings