Fans and cooling management
Thermal Subsystem screen
Fan subsystem status
Row
Thermal Subsystem Status
Redundancy
Fan Location Rule
Fan status
Column
Fan
Model
Status
Fan Speed
When a fan module fails, the remaining fans automatically compensate by adjusting fan speeds.
You can view the status of each fan by selecting the fan bay either through the tree navigation or
the graphical navigation view. The Fan Information screen provides information about the overall
status, the name, the amount of power consumed in watts, the spare part number, and the serial
number. The Fan Information screen also includes diagnostic information such as internal data
130 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices
Description
Indicates the overall status of the fan subsystem. Possible values are Unknown, OK,
Degraded, or Critical Error.
Indicates the redundancy status of the fans. Possible values are Redundant or Not Redundant
The fan location rule indicates the proper location of the fans and the device bays that are
supported.
Description
The bay in the enclosure of the corresponding fan.
The fan model name.
The overall status of the fan. Possible values are Unknown, OK, Degraded, Failed, and
Absent.
Fan speed as a percentage of maximum RPM.