The Line Voltage value is used to provide conversion to Amps for display. The default value is
based on the power supply hardware model, not the actual line voltage. Select the actual line
voltage for the enclosure for a more accurate Amps conversion.
To view updated power meter information, click the Refresh Page button.

Power Subsystem screen

Power supplies available for use in Superdome 2 compute enclosures
All power supplies in one enclosure must have the same part number. The Onboard Administrator
identifies which power supplies must be replaced by displaying a caution icon.
Power Supply summary
The Power Subsystem screen provides status on the power subsystem, on each individual power
supply, and fault conditions.
This screen provides status on the power subsystem and on each individual power supply.
Power Subsystem information
Item
Power Subsystem Status
Power Mode
Redundancy State
Description
The status of the power subsystem. Possible values are Unknown, OK, Degraded, or
Critical Error.
A user setting to configure the enclosure dc power capacity and the input power
redundancy mode of the enclosure. Possible values are Redundant, AC Redundant,
Power Supply Redundant, Not Redundant, or Unknown.
Indicates the redundancy status of the power subsystem. Possible values are Redundant,
Not Redundant, or Redundancy Lost.