Parameter Value Range - Dukane 403570-01 User Manual

Dual servo spin welder
Table of Contents

Advertisement

Parameter Value Range

The minimum and maximum values of the welding
parameters are listed in Table 5-I.
Screen
TOOL Inertia
TOOL Weight
SPIN Decel .
SETUP>
TOP OF STROKE Position
PRE-WELD
TRIGGER Position
Part Pickup Position
Part Pickup Thrust
Part Pickup Timeout
Pre-Spin Orientation
Weld Time/
Weld Rotations/
Weld Distance (Vertical) /
Energy
VERT . Speed
SPIN RPM
SETUP>
WELD
Weld Orientation
Trigger Torque
Torque Trigger Timeout
Constant Torque
Constant Torque Timeout
Hold Speed
Hold Move Time/
SETUP>
Hold Collapse
POST-WELD
Hold Dwell Time
Hold Constant Thrust
TOOLS>
SYSTEM
Home Offset
SETUP
Table 5–I Welding Parameters
Dukane Manual Part No. 403-570-01
Parameter Name
Min.Value
Max.Value
3000 (SVT012VR)
780 (SVT032VR)
0
160 (SVT042VR)
0
25 .0
25
200
0
140 .00
1 .00
140 .00
1 .00
140 .00
1
100
1
60
0
359 .9
0 .01
50000
.01
100 .00
750 (SVT012VR)
5
3000 (SVT032VR)
4000 (SVT042VR)
0
359 .9
1
100
1
60
1
100
1
60
.01
100
0
140 .00
0
100 .00
1
100
0
359 .9
Section 5 - Touch Screen Menus
Resolution
Units
1
kg* cm²
0 .1
kg
1
%
0 .01
mm
0 .01
mm
0 .01
mm
1
%
1
sec .
0 .1
deg .
sec ./
rev ./
0 .01
mm/
Joules
0 .01
mm/s
1
RPM
0 .1
deg .
1
%
1
sec .
1
%
1
sec .
0 .01
mm/s
sec ./
0 .01
mm
0 .01
sec .
1
%
0 .1
deg
Page 47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svt012vrSvt032vrSvt042vr

Table of Contents