Dukane 403570-01 User Manual page 47

Dual servo spin welder
Table of Contents

Advertisement

The bottom right corner of the
contains controls for setting machine behavior when
an out-of-limit condition occurs. The
button specifies if the out-of-limit condition will require
an acknowledgement from the user before allowing the
next cycle to start. This acknowledgement request is
indicated by a button on the bottom of the
as shown in Figure 5-28.
The
Suspect / Bad (Abort)
corner of the screen controls two aspects of machine
function. The first function is to determine if a weld cycle
will be aborted if the process parameter falls outside
the limits. If
Suspect
will complete regardless of the process limit results. If
is chosen, the machine cycle will continue
Bad (Abort)
if any process parameter falls below the Lower limit,
or be terminated if it exceeds the Upper limit for the
following parameters:
Weld Time (s)
Weld Rotations
Peak RPM
Peak Torque (% of max.)
Peak Thrust (% of max.)
Cycle Time (s)
In the case of cycle termination, the machine will report
an error message on the
RUN
for which the limit was exceeded. The second function
is to set the character displayed in the
screen. If the switch is set to
RUN
field will display
if the process was outside the limits.
S
If it is set to
Bad (Abort)
if the process parameter was lower than the Lower
B
limit, and
if the process parameter was higher than
E
the Upper limit.
Dukane Manual Part No. 403-570-01
POST-WELD
Latch on Failure
RUN
button in the right lower
is selected, the machine cycle
screen listing the parameter
field on the
Limits
, the
Suspect
, the
field will display
Limits
screen
screen
Figure 5–28 RUN Screen with PART TEST FAILED
Limits
Section 5 - Touch Screen Menus
Button
Page 41

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svt012vrSvt032vrSvt042vr

Table of Contents