Since the welder press force is limited in jog mode for
safety purposes, the machine will disable the servos
and report an error (
Fault: Jog thrust limit exceeded
OR Vertical servo runaway detected
jogged down too far. If this condition occurs, the welder
must be re-initialized by returning to the RUN screen,
pressing
RESET FAULT
initialization (Step 8).
10. Set Vertical Travel Lower Limit
Position
To protect tooling, set the vertical press travel limit
using the following steps :
1. Navigate to
>
TOOLS
the
VERTICAL TRAVEL LOWER LIMIT
2. Press the
button and wait 1 minute.
Initialize
3. Press the
button, then activate both
DOWN
to move the head down to the posi-
SWITCHES
tion where the lower limit proximity switch should
be activated (at least 4 mm [.15 in.] above tooling
contact, if possible, since the physical hard stop is
lower than the switch position by this distance). To
change speed, select a different setting in the
box.
Jog Speed
4. Press the
Set Position
red circle appears next to the
5. Press
.
DONE
11. Set Weld Process Parameters
Select the desired setup number (1 through 8; setup 1 is
default) from the
TOOLS
Input the desired weld process settings in the
,
, and
WELD
WELD
POST-WELD
menu as described in Chapter 5.
Dukane Manual Part No. 403-570-01
.) if the press is
button, and repeating welder
tab and press
SYSTEM SETUP
button.
VERT .
button, and wait until a flashing
button.
DOWN
>
tab menu.
SELECT SETUP
tabs in the
SETUP
RUN
PRE-
Section 6 - Machine Operation
Page 53