Dukane 403570-01 User Manual page 75

Dual servo spin welder
Table of Contents

Advertisement

Section 8 - Welder Data Export Software
File Write
Sets the write behavior for an existing file. Write Over
overwrites an existing file, while Add On appends data
to the end of the file.
Incoming Data
This indicator will flash when data is being received
from the welder.
EXIT
Exits program.
Profile Graphs
The
tab, shown in Figure 8-2,
PROFILE GRAPHS
contains numerical and graphical representations of the
following weld parameter profiles with respect to time
for the last cycle:
1. Spin Position (rev.)
2. Torque (% of max.) - spin motor torque
3. Vertical Distance (mm)
4. Thrust (% of max.) - vertical actuator thrust
5. Vertical Speed (mm/s)
This data is exported by the welder after each cycle if
the Graph Export option in the System Setup screen is
enabled (see Figure 5-32). It can also be exported on
demand by pressing the
EXPORT LAST WELD GRAPH
button in the Utilities screen (see Figure 5-30).
DATA
Figure 8–2 PROFILE GRAPHS Tab
Plot Data
The profile data is displayed in this box with comma-
separated values.
The first line is a header row,
containing the following parameters: total number of
samples, sampling rate prior to trigger (ms), sampling
rate during weld (ms), sample number at which weld
started, torque trigger setting (% of max. / 10).
Plot
The plot shows all the profile curves (vertical axis)
with respect to time (horizontal axis) in milliseconds.
The icons immediately above the plot contain tools
for a more detailed examination of the plot. Both the
horizontal and vertical scale end values can be changed
by double-clicking on the desired number and entering
a new value.
Page 
Dukane Manual Part No. 403-570-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Svt012vrSvt032vrSvt042vr

Table of Contents