Adjustment Items - Epson Stylus Pro 9000 Service Manual

B0 wide-format professional inkjet printer
Hide thumbs Also See for Stylus Pro 9000:
Table of Contents

Advertisement

EPSON Stylus Pro 9000

5.1.3 Adjustment Items

All parts that require adjustment when being replaced are listed in the table
below. You will also find a list of required adjustment procedures along with the
order of those procedures.
Table 5-2. Service Parts & Required Adjustments
Service
Step
Operation
Number
Printhead
<Start the Self-Diagnostic Function>
replacement
1
Capping position adjustment
2
Head rank input (and initial ink
charge)
Head nozzle check
3
Head slant adjustment (B/C heads)
4
Head Height (Linear) adjustment
5
Bi-D adjustment
6
Head Gap adjustment
7
Test print
8
<Reset the Head unit counter>
9
<Adjust the carriage cover height>
10
Main Board
1
<Parameter backup> *1
replacement
<Firmware update>
2
<Self-Diagnostic Function>
3
Sensor Adjustment
4
Capping position adjustment
5
Head rank input (initial ink charge
6
not necessary)
Bi-D adjustment
7
Head Gap adjustment
8
Flush point adjustment (L/R)
9
Feed adjustment
10
Top/bottom adjustment
11
Rear Sensor position adjustment
12
Test print
13
<Replace the Waste Ink Pads and clear
the counter>
Adjustment
Adjustment Items
Refer to
page 113
page 115
page 112
page 113
page 115
page 134
Table 5-2. Service Parts & Required Adjustments (cont.)
Service
Step
Operation
Number
CR Motor
1
replacement
2
3
4
5
6
7
PF Motor
1
replacement
2
3
4
5
Sensor assembly
1
replacement
P Front
P Edge
Sensor assembly
1
replacement
P Rear
Sensor assembly
1
replacement
P Thick
Sensor assembly
1
replacement
HP Sensor
Sensor assembly
1
replacement
Cover R/L
Sensor
Summary
Adjustment Items
<CR Steel belt tension adjustment>
•Required tool: Tension Gauge
<Self-Diagnostic Function>
Capping position adjustment
Bi-D adjustment
Head Gap adjustment
Flush point adjustment (L/R)
Top/bottom adjustment
Test print
<CR Steel belt tension adjustment>
•Required tool: Tension Gauge
<Self-Diagnostic Function>
Feed adjustment
Top/bottom adjustment
Rear Sensor adjustment
Test print
<Self-Diagnostic Function>
Sensor Adjustment
Top/bottom adjustment
<Self-Diagnostic Function>
Sensor Adjustment
Top/bottom adjustment
<Self-Diagnostic Function>
From the "Test" menu select
"Sensor" and then "Paper
Thickness"
•Required tool: Schema Gauge
<Self-Diagnostic Function>
Capping position adjustment
<Self-Diagnostic Function>
From the "Test" menu select
"Sensor" and then "Cover"
Revision B
Refer to
page 141
page 113
page 115
page 141
page 113
page 126
page 113
page 134
page 127
page 113
page 134
page 127
page 113
page 143
page 113
page 117
page 113
page 144
108