LOWER PAPER GUIDE REMOVAL
When removing/installing the Lower Paper Guide, the
following adjustment procedure is required.
- Cutter Position Adjustment
1. Remove the Maintenance Cover as described in "Maintenance Cover
Removal" on page 73.
2. Open the Front Cover, and remove the eight screws (CP(W2) M3x6)
securing the Lower Paper Guide.
CP(W2) M3x6
Figure 4-11. Location of Lower Paper Guide Screws
Disassembly & Assembly
3. While supporting the Front Cover with your hands, lower the Lower Paper
Guide as shown below.
n
You may find it useful or necessary to move the Front
Cover up/down while removing the Lower Paper Guide.
n
To avoid interfering with the P-Front sensor, pull the top
out towards you as you lower the Lower Paper Guide.
n
When installing Lower Paper Guide, push it all the way up
before tightening the screws; then perform the cutter
position adjustment as described in Chapter 5.
Figure 4-12. Lower Paper Guide Removal
Disassembly Flow