Cr Steel Belt Tension Adjustment; Pf Belt Tension Adjustment - Epson Stylus Pro 9000 Service Manual

B0 wide-format professional inkjet printer
Hide thumbs Also See for Stylus Pro 9000:
Table of Contents

Advertisement

EPSON Stylus Pro 9000

CR STEEL BELT TENSION ADJUSTMENT

This adjustment is necessary for service operations that require you to remove/
loosen the CR Motor or CR Steel Belt. When replacing or re-installing the CR
Steel Belt, you need to confirm the tension of the CR Steel Belt. Tighten or
loosen the screws on the Driven Pulley to increase or decrease the tension.
Standard:
100g ± 10% (at the point where the CR Steel Belt
contacts the CR Rail)
2) Test the tension
in the center.
Driven
Pulley
Figure 5-15. CR Steel Belt Tension
After making sure the tension is 100g
position of the Steel Belt on the Driven Pulley as you
move the carriage back and forth by hand. The Steel
Belt should be in the center of the pulley and must not
slide/drift to one side or the other. If the Belt drifts to
one side loosen the screw on that side a quarter turn
(or tighten the screw on the opposite side a quarter
turn). Test the drift again by manually moving the
carriage. When satisfied the drift is almost completely
gone, test the tension again.
Adjustment
Carriage Assembly
1) Move to
capping position
3) Verify tension
CR
is 100g ± 10%
Motor
10g, look at the
±
Adjustment Steps

PF BELT TENSION ADJUSTMENT

This adjustment is necessary for service operations that require you to remove/
loosen the PF Motor or PF Belt. When replacing or re-installing the PF Belt,
you need to confirm the tension of the PF Belt.
Standard:
3500g ± 10%
Remove the pipe holder and let
the ink tubes hang freely.
Figure 5-16. PF Belt Tension
Revision B
1) Insert the Tension
Gauge hook in the PF
Motor holder hole
2) Pull directly away
from the PF Belt until
the tension gauge
reads 3500g ± 10%
3) Secure the screws
141