4.10 Outer Forward Slide
1
48
2
3
During the folding sequence the fixed clamp presses the interior slide
first against the hold-down and then against the swung-in outer
forward slide 1 at half pressure.
Caution Risk of Injury !
Turn the main switch off.
Set the outer forward slide only with the sewing unit turned off.
Conduct a function test with the greatest possible caution.
Clearance to the interior slide
–
Loosen lock nut 3.
–
Set the tie rod 2
The outer forward slide should, in its initial position, have a
clearance of 1 to 2 mm to the interior slide.
–
Tighten lock nut 3.
Sideways position
–
Loosen screw.
–
Align the position of the outer forward slide on the carrier.
–
Tighten the screws.
Conduct a function test
–
Set the program switch to 41 and press the " STOP " key.
With the " REPEAT " key run through the function sequence in
interval operation.