2.5.2 Height Adjustment Range

14
When the lowest stroke position is in effect the pressure foot at the
lower dead center should have a clearance of 2.5 mm to the needle
hole mushroom.
Caution Risk of Injury !
Conduct adjustment work and function testing only with greatest
possible caution.
Lower the sewing head.
Set the program switch to 44 and press the " STOP " key.
The sewing head is lowered and the needle plate and pressure
foot raised.
Loosen the wing nut 4 and arrest the lever 5 in the lowest position.
Loosen nut 1.
Press bolt 2 down to the end of the slot.
Tighten nut 1.
Pull lever 3 forward until the piston rod of the cylinder is run out
completely.
With the handwheel bring the pressure foot into the low position.
Screw off the head cover 8.
Loosen screw 6.
Set the presser bar 7.
The clearance between the pressure foot and the needle hole
mushroom must be 2.5 mm.
Tighten screw 6.
Screw the head cover 8 on again.
ATTENTION !
After setting the height adjustment range set the pressure foot stroke
position ( see Operating Instructions ).