Switching Disks; Function Of The Switching Disks - Duerkopp Adler 975-1-5 Service Instructions Manual

Hide thumbs Also See for 975-1-5:
Table of Contents

Advertisement

4.4 Switching Disks

4.4.1 Function of the Switching Disks

36
The switching disks no.s 1 to 10 trigger the function of various
clamping table elements via the pneumatic valves.
Switching Disk
No. 1
No. 2 and 3
No. 4
No. 5
No. 6
No. 7 and 8
No. 9 and 10
Function
Forward slide - Inner
forward and back
Fixed clamp and sleeve clamp
of the fixed table
close (full pressure)
close (half pressure)
open and pressure-free
Swing clamp
open and close
Sleeve clamp of the sleeve table
open and close
Hold-down
hold open and closed
Interior slides
forward and back
Trim clamp cylinder for swing clamp
open and close
Cross clamp cylinder for swing clamp
Piston rod run in
Cylinder pressure-free
Piston rod run out
(with half and with full pressure)

Advertisement

Table of Contents
loading