2.3.3 Timing of the Switch Operation

8
1
2
3
In the upper position of the needle plate switch 2 ( b20 ) should be
triggered by the strip 3.
In the lower position of the needle plate switch 1 ( b19 ) should be
triggered by the strip 3.
Caution Risk of Injury !
Conduct adjustment work and function testing only with greatest
possible caution.
Upper position switch
Set the program switch to 63 and press the " STOP " key.
Set the program switch to 20.
Bring the needle plate manually into the lower position.
The display must show "- b20 ".
If not, the switch position must be corrected.
Lower position switch
Set the program switch to 63 and press the " STOP " key.
Set the program switch to 19.
Bring the needle plate manually into the upper position.
The Display must show "- b19 ".
If not, the switch position must be corrected.
1
2