Mv Station Error Messages - Canon WebView LivescopeMV User Manual

High-performance monitoring software
Hide thumbs Also See for WebView LivescopeMV:
Table of Contents

Advertisement

(15) When the background image view size has reached the maximum
Message
Cause
Action to
be taken

MV Station Error Messages

(16) Could not get in camera control right queue
Message
Cause
Action to
be taken
(17) When switching to appropriate camera failed during assignment
Message
Cause
Action to
be taken
(18) Power to the camera is turned off or there is a malfunction
Message
Cause
Action to
be taken
(19) Incorrect address
Message
Cause
Action to
be taken
116
This file exceeds the maximum view size (1280
The specified background image size is larger than the maximum view size of 1280 x 1024.
For the background image, specify a file with a view size smaller than 1280 x 1024.
Could not get in camera control right queue.
Another client with camera control privileges of a higher level than yourself is
connected to the camera server.
Ask the other client to release the camera control privileges.
Could not switch camera.
An attempt was made to assigned a camera that is different from the camera
being viewed by a client with control rights of a higher level than yourself.
Ask the other client to release the camera control privileges.
Camera is switched off or faulty.
Power to the camera is off, or a cable is not properly connected.
• Turn on power to the camera.
• Connect the cable.
Could not connect to the camera server.
Network connection was cut, power to the camera server was cut, or the proxy
settings are not correct.
• Re-connect to the network.
• Turn on power to the camera server.
• Redo the proxy settings.
1024). Specify another file.