Symptoms: Partner blade errors
Error indication
Insight Display reports error on
suspect partner blade
Partner blade health LED is off
Partner blade health LED is
amber
Partner blade health LED is
green, but another LED on this
partner blade is red
Procedures: Partner blade errors
CAUTION:
avoid possible data loss, always secure permission before powering down an enclosure.
CAUTION:
Display shows a firmware update in progress. During this activity, the Insight Display displays
the Firmware Update screen with the Lock icon and the firmware update progress bar.
Step
Step 1
Step 2
Initial step
For proper installation and support,
most partner blades require a partner
server blade to be installed and
powered off during partner blade
installation. If the partner blade is
installed while the partner server blade
is powered up, then power down the
partner server blade before powering
up the partner blade. Partner blades for
interconnect modules require the
interconnect module to be installed for
operation.
Some troubleshooting procedures require powering down an entire enclosure. To
To avoid data loss, do not remove an Onboard Administrator when the Insight
Partner blade errors action and verification
Action
Examine device bay status for the suspect partner blade on the Insight Display Health
Summary.
Verification
If the Insight Display device bay status for the partner blade is black, then continue to
the next step.
If the Insight Display device bay status for the partner blade is blue, yellow, or red, then
follow the Insight Display directions to correct the issue.
Action
Reseat the partner blade.
Verification
If the Insight Display device bay status for the partner blade is black, then continue to
the next step.
If the Insight Display device bay status for the partner blade is blue, yellow, or red, then
follow the Insight Display directions to correct the issue.
Required steps
To correct the issue, follow the
Insight Display steps.
Begin with step 1
To correct the issue, follow the
Insight Display steps.
For LED information, see the
partner blade documentation.