Error indication
A server blade does not power up.
The following conditions exist:
•
The power LED is amber.
•
The health LED is off.
•
The Insight Display device bay
status is dark green.
A server blade does not power up.
The following conditions exist:
•
The power LED is amber.
•
The health LED is flashing amber.
•
The Insight Display device bay
status is dark green.
A server blade is powered up.
The following conditions exist:
•
The power LED is green.
•
The health LED is green.
•
The Insight Display device bay
status is blue.
Initial step
—
—
No iLO 2 IP address results in
the following conditions:
•
No iLO 2 web or SSH
access
•
No enclosure DVD-ROM
drive support for this server
blade
•
No server blade
information provided to the
Onboard Administrator
•
No remote console or
remote media support
Required steps
Press the server blade Power
On/Standby button. If the server
blade does not power on, then begin
with step 4.
Troubleshoot the processor to correct
the issue. Perform the following steps
as instructed in the server blade
documentation:
1
Remove the server blade.
2
Remove the processor.
3
Install a spare processor.
4
Install the server blade in the
original device bay.
5
If the server blade powers up,
then the repair is complete. If the
server blade does not power up,
then replace the server blade.
iLO 2 on this server blade has no IP
address.
To configure the iLO 2 IP address,
reboot the server blade and use the
iLO 2 ROM setup during POST.
Enclosure troubleshooting 37