Table 4. NDIS (Windows 2000 or Windows XP) Event Viewer messages for the Ethernet controller (continued)
Error code
Description
(hex)
0x0E
Explanation: Could not allocate enough memory for receive queue.
Action:
v If you have Windows 2000, do the following:
1. From the Windows 2000 desktop, click Start"Control Panel"Networks"Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Click Properties"Advanced.
4. Lower the resource values that apply to the transmit queue.
v If you have Windows XP Professional, do the following:
1. Click Start"Control Panel"Network Connections"Local Area Connection.
2. Select your IBM Ethernet adapter from the list.
3. Click Properties"Advanced.
4. Lower the resource values that apply to the transmit queue.
0x0F
Explanation: Could not allocate enough memory for other structures.
Action:
v If you have Windows 2000, do the following:
1. From the Windows 2000 desktop, click Start"Control Panel"Networks"Adapters.
2. Select your IBM Ethernet adapter from the list.
3. Click Properties"Advanced.
4. Lower the resource values that apply to the transmit queue.
v If you have Windows XP Professional, do the following:
1. Click Start"Control Panel"Network Connections"Local Area Connection.
2. Select your IBM Ethernet adapter from the list.
3. Click Properties"Advanced.
4. Lower the resource values that apply to the transmit queue.
0x10
Explanation: Did not find any Ethernet controllers.
Action: Contact the network administrator. The driver may need to be reinstalled. If the problem
persists, run diagnostics to determine if the hardware has failed.
0x11
Explanation: Multiple Ethernet controllers found, but none matched the required ID.
Action: Contact the network administrator. The driver may need to be reinstalled. If the problem
persists, run diagnostics to determine if the hardware has failed.
0x13
Explanation: Did not find any Ethernet controllers that matched the required subven/subdev.
Action: Contact the network administrator. The driver may need to be reinstalled. If the problem
persists, run diagnostics to determine if the hardware has failed.
0x16
Explanation: Single adapter found, but multiple instances tried to load.
Action: Contact the network administrator. The driver may need to be reinstalled. If the problem
persists, run diagnostics to determine if the hardware has failed.
0x17
Explanation: Slot parameter not specified in the registry.
Action: Contact the network administrator. The driver may need to be reinstalled. If the problem
persists, run diagnostics to determine if the hardware has failed.
21
Diagnostics