Specific Problems And Corrective Actions - Acer AT350 F2 Series Service Manual

4u dual socket rack-mountable tower server
Hide thumbs Also See for AT350 F2 Series:
Table of Contents

Advertisement

Specific problems and corrective
actions
Listed below are specific problems that may arise during the use of your
server and their possible solutions.
Power indicator does not light.
Do the following:
Make sure the power supply module is properly installed.
Make sure the power cord is connected correctly.
Make sure that the wall outlet has power. Test it by plugging in another
device.
Make sure the power indicator on the front panel is lit up.
Remove all add-in cards and see if the system boots.
If reboot is successful, install the cards back in one at a time with a
reboot between each addition to determine if one of them is causing
the problem.
Make sure that you have properly installed system compliant memory
modules, and that they are populated according to the system
guidelines.
Make sure that you have installed system compliant processors, and
that they are populated according to the system guidelines.
HDD activity indicator does not light.
Do the following:
Make sure the drive is not disabled in the BIOS Setup Utility.
Make sure the drive is compatible
Make sure you have not exceeded the power budget for the server.
Check that relevant switches and jumpers on the hard drive and on the
backplane board are set correctly.
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents