Server Configuration and Utilities
RBSU Access
To access the redundant ROM through RBSU:
1. Access RBSU by pressing the F9 key when prompted at startup.
2. Select ROM Selection in the Advanced Options menu of RBSU.
3. Select one of the ROM banks as the system ROM.
4. Press the Enter key.
5. Press the Esc key to exit the current menu or press the F10 key to exit RBSU.
6. Restart the server.
Manual Access
To access the redundant ROM manually
1. Power down the server. Refer to Chapter 2, "Server Operations."
2. Remove the front bezel. Refer to Chapter 2, "Server Operations."
3. Remove the access panel. Refer to Chapter 2, "Server Operations."
4. Set the system configuration switch positions 1, 5, and 6 to the On position.
For the location of the system configuration switch, refer to Chapter 1,
"Component Identification."
5. Power up the server. Refer to Chapter 2, "Server Operations."
The ROM will beep and halt when the ROM images have been swapped.
6. Power down the server and reset all system configuration switch positions to the
default Off position.
7. Power up the server.
If both the current and previous versions of the ROM are corrupted, refer to
"ROMPaq Disaster Recovery" in Appendix D, "Server Specific Troubleshooting."
When the server boots, it identifies whether the current ROM bank is corrupt. If a
corrupt ROM is detected, the server boots from the backup ROM and alerts you
through POST that the ROM bank is corrupt.
5-10
HP ProLiant ML330 Generation 3 Server Setup and Installation Guide