Appendix A Specifications
Model
N5741A
N5761A
Series and Parallel Capability:
Parallel operation
Up to 4 identical units can be connected in master/slave mode with single–wire current balancing
Series operation
Up to 2 identical units can be connected using external protection diodes
Savable states:
In volatile memory
16 (in memory locations 0-15)
Interface Capabilities:
GPIB
SCPI - 1993, IEEE 488.2 compliant interface
LXI Compliance
Class C (only apples to units with the LXI label on the front panel)
USB 2.0
Requires Agilent IO Library version L.01.01 and up, or 14.0 and up
10/100 LAN
Requires Agilent IO Library version L.01.01 and up, or 14.0 and up
Environmental Conditions:
Environment
Indoor use, installation category II (AC input), pollution degree 2
Operating temp.
0C to 40C @ 100% load
Storage temp.
–20C to 70C
Operating humidity
Up to 90% relative humidity (no condensation)
Storage humidity
10% to 95% relative humidity (no condensation)
Altitude
Up to 3000 meters.
Above 2000m, derate the output current by 2%/100m and derate the maximum ambient temperature by 1C/100m.
(For 1500W models from 60V to 600V, derate either the output current or the ambient temperature, but not both.)
Regulatory Compliance:
EMC
Complies with European EMC Directive for test and measurement products.
● IEC/EN 61326-1
● CISPR 11, Group 1, class A
● AS/NZS CISPR 11
● ICES/NMB-001
Complies with the Australian standard and carries the C-Tick mark.
This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada.
Safety
Complies with the European Low Voltage Directive and carries the CE-marking.
Conforms to UL 61010-1 and CSA C22.2 61010-1.
Acoustic Noise Declaration:
Statements provided to comply with requirements of the German Sound Emission Directive, from 18 January 1991:
Sound Pressure Lp <70 dB(A), * At Operator Position, * Normal Operation, * According to EN 27779 (Type Test).
Schalldruckpegel Lp <70 dB(A) * Am Arbeitsplatz, * Normaler Betrieb, * Nach EN 27779 (Typprüfung).
Output Terminal Isolation:
6V to 60V units
No output terminal may be more than +/- 60 VDC from any other terminal or chassis ground
80V to 600V units
No output terminal may be more than +/- 600 VDC from any other terminal or chassis ground
AC Input:
Nominal Input
100 – 240 VAC; 50/60Hz
Input Current 750W
10.5A @ 100 VAC nominal; 5A @ 200 VAC nominal
Input Current 1500W
21A @ 100 VAC nominal; 11A @ 200 VAC nominal
Input Range
85 – 265 VAC; 47 – 63 Hz.
Power Factor
0.99 at nominal input and rated output power
Efficiency
76% – 87% for 750W units; 77% – 88% for 1500W units
Inrush Current
< 25A for 750W units; < 50 A for 1500W units
90
Agilent Models N5741A – N5752A and N5761A – N5772A
N5742A
N5743A
N5744A
N5762A
N5763A
N5764A
N5745A
N5746A
N5747A
N5765A
N5766A
N5767A
N5748A
N5749A
N5750A
N5768A
N5769A
N5770A
Series N5700 User's Guide
N5751A
N5752A
N5771A
N5772A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents