−231
−232
−233
−240
−241
−260
−261
−400
−410
−420
−430
−440
Series N5700 User's Guide
Execution Errors (continued)
Data questionable
The measurement accuracy is suspect.
Invalid format
The data format or structure is inappropriate.
Invalid version
The version of the data format is incorrect to the instrument.
Hardware error
The command could not be executed because of a hardware problem with the instrument.
Hardware missing
The command could not be executed because of missing hardware, such as an option.
Expression error
An expression program data element related error occurred.
Math error in expression
An expression program data element could not be executed due to a math error.
Query Errors (these errors set Standard Event Status register bit #2)
Query Error
Generic error query
Query INTERRUPTED
A condition causing an interrupted query error occurred.
Query UNTERMINATED
A condition causing an unterminated query error occurred.
Query DEADLOCKED
A condition causing a deadlocked query error occurred.
Query UNTERMINATED after indefinite response
A query was received in the same program message after a query indicating an
indefinite response was executed.
Service Appendix C
121