Load Considerations - Agilent Technologies N5700 Series User Manual

System dc power supply
Hide thumbs Also See for N5700 Series:
Table of Contents

Advertisement

2 Installation
NOTE

Load Considerations

Multiple Loads
26
To configure the power supply for remote sensing:
Turn off the power supply.
Remove the local sense jumpers from the J2 connector.
Connect the negative sense lead to terminal 5 (-S) and the
positive sense lead to terminal 1 (+S). Make sure that the
connector plug is securely inserted into the connector body.
Turn on the power supply.
+V
Power
Supply
-
Rem.sense
-
Local sense
+L
ocal sense
+
Rem.sense
If the power supply is operated with remote sensing and either the positive or
negative load wire is not connected, an internal protection circuit will activate
and shut down the power supply. To resume operation, turn the power supply
off, connect the open load wire, and turn on the power supply.
The following figure shows multiple loads connected to one power
supply. Each load should be connected to the power supply's output
terminals using separate pairs of wires. It is recommended that each
pair of wires will be as short as possible and twisted or shielded to
minimize noise pick-up and radiation. The sense wires should be
connected to the power supply output terminals or to the load with
the most critical load regulation requirement.
+V
Power
-V
Supply
-
Rem.sense
-
Local sense
+L
ocal sense
+
Rem.sense
Load lines. Twisted pair
shortest length possible.
-V
Load lines, twisted pair,
shortest length possible.
+
Load
Sense lines.
Twisted pair or
shielded wires.
+
Load#1
+
Load#2
+
Load#3