Enable/Disable Terminals
CAUTION
SW1 switch 9
Down (default)
Up
Series N5700 User's Guide
To re-enable the output after it has shut down, you must disable the
Shut-Off signal. In Auto-Restart mode, operation resumes
automatically. In Safe-Start mode the Shut-Off function is latched.
You must also press the OUT ON button or send an
OUTPut:PROTection:CLEar command to resume operation.
The Shut-Off function can be used to shut down multiple power
supplies in a daisy-chain fashion as explained later in this chapter. It
can also be used to reset the OVP and OCP as previously described.
SW1 switch 5
Down (default)
Up
Because this function is edge-triggered, it may not be triggered by every state
NOTE
change. For example, after applying AC power, the output will not be disabled
by the Shut Off function if the Shut-Off input is in the shut-off state. This is
because the unit has not detected an on-to-off signal transition.
To prevent possible damage to the unit, do not connect the Enable + or Enable –
terminals to the positive or negative output terminals.
Enable/Disable terminals are available on the J1 connector to enable
or disable the power supply output. This function is level-triggered.
Simply connect a switch or relay between J1 pins 1 and 14. This
function is activated by SW1 setup switch 9.
These pins disable the output when they are opened. When the
output is disabled, the PROT indicator on the front panel will blink.
To re-enable the output after it has shut down, you must short the
Enable + and Enable – terminals. In Auto-Restart mode, operation
resumes automatically. In Safe-Start mode the Enable/Disable
function is latched. You must also press the OUT ON button or send
an OUTPut:PROTection:CLEar command to resume operation.
ENA+/ENA– pins
Not active
Opened
Shorted
Operating the Power Supply Locally 3
SO Signal Level
Output
2 - 15 V or Open
On
0 – 0.4V or Short
Off
2 - 15 V or Open
Off
0 – 0.4V or Short
On
Output
Display
On
Voltage/Current
Off
ENA
On
Voltage/Current
Display
Voltage/Current
SO
SO
Voltage/Current
Prot Indicator
Off
Blinking
Off
41