Chapter 3
11. The Embedded LAN and SCSI Settings submenu is displayed. If
HP NetRAID/LVD SCSI is not already highlighted, use the up and down
arrows to highlight it.
Read the values in the brackets to determine whether LVD SCSI is
enabled.
Enable LVD SCSI indicates that LVD SCSI is enabled and
HP NetRAID is disabled. This is the correct setting for non-RAID
operation of the mass storage cages connected to SCSI A and B on the
I/O baseboard.
Enable HP NetRAID indicates that HP NetRAID is enabled to
provide RAID operation of the mass storage cages connected to
SCSI A and B on the I/O baseboard. This is the default value.
CAUTION
If your HP NetServer was previously operating in RAID mode
(Enable HP NetRAID), changing to non-RAID mode (Enable
LVD SCSI) could cause data loss. Be sure your data is backed
up before you change to non-RAID mode.
If the value is not Enable LVD SCSI, use the +/- keys to change it to
Enable LVD SCSI. This change will take effect when the HP NetServer
restarts.
Exit Setup Utility
12. Press the F10 function key to save and exit.
13. In the Setup Confirmation dialog box, press Enter to answer "Yes" to the
question, "Save configuration changes and exit now?" The HP NetServer
will restart.