The message "Configuration of NVRAM and drives mismatch"
indicates that configuration information in the integrated HP
NetRAID controller's NVRAM differs from configuration
information in hard disk drives.
Do the following to clear configuration information from
integrated HP NetRAID NVRAM:
1. Press Ctrl+M to start the HP NetRAID Express Tools utility.
2. On the Tools Management Menu, choose Configure.
3. On the Configure menu, choose Clear Configuration.
until the Exit? box appears. Choose YES to exit. Then press
Ctrl+Alt+Del to restart the NetServer.
2. As soon as you see the message
Press <F2> to enter SETUP
on the display monitor, press the F2 function key.
NOTE
If you wait too long to press the F2 function key, you may not
be able to enter the Setup utility, even though the message
"Press <F2> to enter SETUP" is still displayed. If this happens,
restart the HP NetServer, and press the F2 function key as soon
as the message appears.
3. If a power-on password has been set, provide it when prompted.
32
If the question "Clear Configuration?" is displayed, answer
Yes. Then press any key to continue, and go to Step 4 in
this note.
If the message "No Existing Configuration to Clear" is
displayed, press Esc to return to the Configuration menu,
choose New Configuration, and answer Yes to the
question "Proceed?". When the scan finishes, all drives are
shown in the Ready state. Press Enter to end the array, and
answer Yes to the "Save Configuration?" question. When
"Configuration is Saved" is displayed, press any key.
To exit HP NetRAID Express Tools, press ESC repeatedly
Configure Mass Storage