HP D7171A - NetServer - LPr Upgrade Manual page 30

Mass storage upgrade guide
Hide thumbs Also See for D7171A - NetServer - LPr:
Table of Contents

Advertisement

Chapter 2
Light pipes on the module transmit light to these apertures from LEDs on the
inside rear of the hot-swap mass storage cage. Verify that the LEDs show the
correct status and activity indications for all of the disk drive modules that you
installed:
1. Turn on power to the HP NetServer and display monitor.
2. During the Power On Self Test (POST) early in the boot sequence, watch
the two LED indicators on each hard disk drive module.
Status LEDs: All LEDs quickly cycle from amber to steady green.
Activity LEDs: All LEDs quickly cycle from amber to green. The
LED stays steady green until the drive spins up.
3. If no LED indicators were illuminated on any disk drive modules, the
power harness may not be correctly connected. Check it as follows:
a. Turn off the HP NetServer power switch and unplug the AC power
cords and any telephone cables. Remove the front bezel and Cover 1, as
described in Steps 1 and 2. Remove the fan assemblies as described in
Step 5.
b. Disconnect the P2 connector of the power harness, and reconnect it as
described in Step 7.
c. Replace the fan assemblies as described in Step 8. Replace Cover 1 and
the front bezel as described in Step 9. Reconnect the AC power cords
and any telephone cables.
d. Restart the HP NetServer to determine whether the LED indicators
become illuminated during the POST now. If not, contact your reseller.
26