A Specifications

Introduction

This appendix provides the power requirements, operating conditions
(environment requirements), physical requirements, hardware specifications, and
video resolutions of the HP NetServer E 200. The system board layouts and the
factory set jumpers are also provided. See Figures A-1 and A-2.
The specifications and requirements listed below can vary if you install a mass
storage device in the NetServer that has more stringent environmental limits.
Ensure the operating environment for the mass storage devices you intend to
install are compatible with the NetServer environment requirements.

Requirements

The following tables provide the specifications for the HP NetServer E 200
required for normal operation.
Table A-1. Power Supply Specifications
Parameter
Input Type
Input – Maximum Range
Operating Current
In-rush Current
Operating Power
Characteristics
Auto-ranging
100 to 120 VAC 4.6 A at 50/60 Hz
(Mexico = 4,6 A at 50/60 Hz)
200 to 240 VAC 2.8 A at 50/60 Hz
(Mexico = 2,8 A at 50/60 Hz)
100 VAC 5.3 A
(Mexico = 5,3 A)
120 VAC 4.6 A
(Mexico = 4,6 A)
200/208 VAC 3.2 A
(Mexico = 3,2 A)
220/230 VAC 2.8 A
(Mexico = 2,8 A)
25 A
256 W continuous
305 W maximum continuous