Table of Contents

Advertisement

Chapter 9
4. If necessary remove the accessory board preventing access to the battery.
5. Insert a small flat blade screwdriver or similar tool between battery and
spring latch. See Figure 9-2.
6. Push the spring latch away from battery to release the battery.
The spring contacts beneath the battery cause it to pop up allowing you to
grasp the battery.
7. Remove the existing battery.
8. Insert the new battery with the positive sign (+) facing up into the socket.
9. Press down on the center of the battery with your thumb pushing the
battery down into the socket.
The battery should snap into place.
10. Ensure the spring latch holds the battery firmly.
11. Replace the cooling duct/cover and the NetServer cover.
12. Power on the NetServer and reset the settings in the (BIOS) Setup Utility.

Setup Utility Problems

If you cannot run the Setup Utility, the NetServer's configuration in CMOS
memory may have become corrupt. The only way to recover from a corrupted
configuration is to clear it. Refer to "Clearing the CMOS Configuration," earlier in
this chapter.