Chapter 9
Message
Corrective Action
Operating system
not found
CMOS checksum
If the checksum of the CMOS is incorrect, the NetServer
error
loads the default BIOS configuration. A checksum error may
indicate the CMOS has been corrupted or the battery is
weak.
Hardware Monitor
The Hardware Monitor is a submenu of the Power menu
found an error
listed in the menu bar of the Setup Utility. If any of the items
in the monitored list are out of range, this error message will
appear. This error message will give you two options:
NOTE
If a NetServer configuration error is reported during the startup
routine (boot messages), clear the CMOS memory as described
under "Clearing the CMOS Configuration," and restart the
NetServer.
Verify the boot drive has power and the correct data
(IDE or SCSI) cables connected.
Verify the hard drive cable is securely plugged into the
system board (for IDE drives) or the SCSI controller
board (for SCSI drives).
Verify the boot device is enabled in the Boot menu
(IDE or SCSI).
Verify the boot device has a NOS installed.
If the problem persists, contact your HP support
organization.
Enter [Del] the Setup Utility, reset to defaults and
make changes to factory settings. See Table 8-2.
Press F10 to save changes and Exit.
The NetServer will reboot.
If the problem persists, replace the battery or reinstall
the BIOS and contact your HP support organization.
Press <F1> to continue – This allows you to complete
the boot process.
Press <Del> to enter the Setup Utility – This allows
you to view the item or items out of range.
Troubleshooting
65