Status Read Command - Sanyo PLC-XTC50AL Service Manual

Hide thumbs Also See for PLC-XTC50AL:
Table of Contents

Advertisement

Chassis Description

Status read command

Format
The command is sent from PC to the projector with the format below;
'CR' [Command] 'CR'
Command: one character (refer to the command table below.
The projector decodes the command and returns the 'Character string' with the format below;
command
Function
CR0
Status Read
CR6
Temperature Read
The tables show the typical command lists for controlling the projector. Please consult your local dealer for
further information of other commands.
This Serial port does no available in the Eco standby mode. To use this function in the standby mode, the Normal
standby mode should be selected.
Projector return
00
Power On
80
Stand-by mode
40
Countdown
0
Cooling down
10
Power Malfunction
8
Cooling down at the temperature anomaly
4
Cooling down at Power Management mode
04
Power Management mode after Cooling down
1
Cooling down after the projector is turned off when the lamps are out.
81
Stand-by mode after Cooling down when the lamps are out.
88
Stand-by mode after Cooling down at the temperature anomaly.
Cooling down when the projector is turned off by the shutter management
C
function.
8C
Stand-by mode after cooling down by the shutter management function.
S1 = Temperature at Sensor 1 (Temp A) (˚C)
S = Temperature at Sensor  (Temp B) (˚C)
S3 = Temperature at Sensor 3 (Temp C) (˚C)
S1 S S3
(ex.) S1 = 1.3˚C, S = 3.4˚C, S3 = 34.5˚C
--> The projector displays "1.3 3.4 34.5"
( For each sensor, two digit and the tenth place numbers are displayed
with a space between each temperature.)
?