[Rcu] Change Rcu Option - HP StorageWorks P9000 Reference Manual

Audit log user and reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Item
RCU
SSID
MCU Port
RCU Port
Min.Path
MIH Time(s)
Round Trip Time(ms)
FREEZE
Num. of Port Pairs

[RCU] Change RCU Option

Example 1: CU Free is used
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[RCU],Change RCU Option,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{S/N,MCU LDKC,RCU LDKC,Path Gr.ID,Controller ID,Min.Path,
MIH Time(s),Round Trip Time(ms),FREEZE}
={99999,0x00,0x00,Default,4,08,015,001,Disable}
Example 2: CU Free is not used
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,,
[RCU],Change RCU Option,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{S/N,MCU LDKC,MCU,RCU LDKC,SSID,Controller ID,Min.Path,
MIH Time(s),Round Trip Time(ms),FREEZE}
={99999,0x00,0x3F,0x00,0x0004,4,08,015,001,Disable}
Detailed information
Item
S/N
MCU LDKC
RCU LDKC
Path Gr.ID
Controller ID
MCU
SSID
Min.Path
MIH Time(s)
Description
The CU number of the paired CU.
The SSID of the registered RCU.
The port number of MCU.
The port number of the registered RCU.
The number of set minimum paths.
The value of set RIO MIH (Remote I/O Missing Interrupt Handler) timer (wait time until data
copy from MCU to RCU is completed). The unit is second.
The round-trip response time set (delay time for round-trip remote I/O). The unit is millisecond.
This value is output when Continuous Access Synchronous or Continuous Access Synchronous
Z is used.
Indicates whether CGROUP (FREEZE/RUN) PPRC TSO command support is enabled or disabled.
This value is output only when Continuous Access Synchronous Z is used.
Enable or Disable is output.
The number of port pairs set.
Description
Indicates a serial number of the RCU device where the RCU option setting is changed.
The LDKC number of the connected LDKC.
The LDKC number of the paired LDKC.
The RCU path group ID where the RCU optional setting is changed. When the path group ID
is default setting, "Default" is output.
The controller ID of the RCU where the optional setting is changed.
The CU number of the connected CU.
Indicates SSID of the RCU where the optional setting is changed.
The minimum number of paths after change.
The value of RIO MIH (Remote I/O Missing Interrupt Handler) timer (wait time until data copy
from MCU to RCU is completed). The unit represents seconds.
RCU descriptions
147