Example 4: replacing a PDEV (physical device)
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance], Replace,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD000-00
+Copy=Restore Data
Example 5: replacing a SSW
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance], Replace,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+SSW=[SSW000-LP1,SSW001-LP1],Num. of SSWs=2
Example 6: replacing a SSD
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Maintenance], Replace,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+SSD=SSD0(CACHE-1CA),Num. of SSDs=1
Detailed information
Item
Parts name
SFP
Num.of SFPs
PCB
Failed
Num. of PCBs
Physical Device
(PDEV)
Copy
Diagnosis
Micro Program
SSW
Num. of SSWs
SSD
Num. of SSDs
98
Audit log examples
Description
The name of the parts (DKCPS-xx, DKCFAN-xxx, DKCPANEL-x,SSVPMN-x, PCIADP, PCICON,
BATTERY-xxx, SVP-BASIC, SVP-OPTION, HUBBOX-xx, HDDPWR-xxxx, DKUPS-xxx, HDDFAN-xxx)
specified to be replaced.
The port that Small Form-Factor Pluggables (SFPs) are inserted.
The number of inserted Small Form-Factor Pluggables.
The mounting location of the PCB, (Channel Adapter (CHA), Disk Adapter (DKA), cache
memory, CM, or ESW) to be replaced.
When replacing multiple PCBs and some of the PCBs to be replaced had failures, the mounting
locations of the failed PCBs are indicated. In such case, "Warning" is output as the result of
the process.
Note: This information is not output when there are no failed PCBs.
The number of PCBs to be replaced.
The mounting location of the PDEVs (physical devices) to be replaced.
The status of copy process when replacing physical devices (PDEV)s. This information is output
only when replacing PDEVs.
Restore Data: Data recovery from spare disk, Correction Copy: correction copy
Diagnosis is output only when INLINE skip is selected when replacing PDEVs. This information
is output only when replacing PDEVs.
Micro Program is output only when microcode update is skipped when replacing PDEVs. This
information is output only when replacing PDEVs.
The mounting location of SSWs to be replaced.
The number of SSWs to be replaced.
The mounting location of SSDs in the CM package
The number of SSDs