[Install] Set Battery Life; [Install] Set Channel Speed; [Install] Set Commanddev - HP StorageWorks P9000 Reference Manual

Audit log user and reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Detailed information for example 2
Item
New Ver.
Old Ver.

[Install] Set Battery Life

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set Battery Life,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Use Battery
Life,Date,Remained Life}={Valid,YYYY/MM/DD,610}
Detailed information
Item
Use Battery Life
Date
Remained Life

[Install] Set Channel Speed

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set Channel Speed,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Port,Speed(Gbps)}=[{XX,1},{XX,2},{XX,Auto}],
Num. of Ports=3
Detailed information
Item
Port
Speed(Gbps)
Num. of Ports

[Install] Set CommandDev

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Set CommandDev,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{LDKC:CU:LDEV,CommandDev}=[{0x00:0xXX:0xXX,Disable},
{0x00:0xXX:0xXX,Enable}],Num. of LDEVs=2
86
Audit log examples
Description
The new version number.
The old version number.
Description
The status of Battery life function set.
Valid: Valid, Invalid: Invalid
Indicates the date of the setting in "YYYY/MM/DD " format (YYYY: year, MM: month, DD: day).
A hyphen (-) is indicated when the information is not set.
The remaining date of the battery shelf life. A hyphen (-) is output when the information is not
set.
Description
The name of the port on which the channel speed is set.
The channel speed set.
1: 1 Gbps, 2: 2 Gbps, 4: 4 Gbps, 8: 8 Gbps, Auto: Auto mode.
The number of ports where the channel speed is set.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9500

Table of Contents