[Ext Stor] Edit Es Vols; [Ext Stor] Edit External Wwns - HP StorageWorks P9000 Reference Manual

Audit log user and reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

[Ext Stor] Edit ES VOLs

Example 1: Change the cache mode
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Ext Stor],Edit ES VOLs,CacheMode,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Group,Result}
=[{E1-1,Enable,Normal end},{E1-2,Enable,Normal end},
{E1-3,Enable,Normal end},{E1-4,Enable,Normal end}],
Num. of Groups=4
Example 2: Set the cache inflow control
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Ext Stor],Edit ES VOLs, InflowControl,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{Group,Mode,Result}=[{E1-1,Enable,Normal end},
{E1-2,Enable,Normal end},{E1-3, Enable,Normal end},
{E1-4, Enable,Normal end}],Num. of Groups=4
Basic information
Parameter
Cachemode
InflowControl
Detailed information
Item
Group
Mode
Result
Num. of Groups

[Ext Stor] Edit External WWNs

Example
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,uid=user-name,1,
Task Name,[Ext Stor],Edit External WWNs,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{WWN,I/O-TOV,Quedepth,LinkDown,Result}
=[{50060E8000C3E214,15,8,180,Normal end},
{50060E8000C3E214,15,8,180,Normal end},
{50060E8000C3E214,15,8,180,Normal end},Num. of WWNs=3
Description
The cache mode is changed.
The cache inflow control is set.
Description
External volume group number for the executed setting operation.
Whether the setting is enabled or disabled.
Enable: Enabled, Disable: Disabled
The result of operation.
Normal end: Normal end, Error (xxxx-yyyyy): Abnormal end
xxxx: Part code, yyyyy: Error code
The number of external volumes groups configured.
External Storage descriptions