=[{CLPR0,84992,1024,16384}],Num. of CLPRs=1
+PP Flag=[<64KLDEV, SI/VM Extension1, FCV2, DP, CoW, TPF>,
<SI/VM Extension2, CoW Extension>],Num. of PP Flags=2
+Max Number of CUs=64
Detailed information for example 3
Item
Description
CM
The mounting location of the PCB for cache memory.
CMG
The capacity of the CMG.
Size
The capacity of the cache memory.
SSD0
The size of the SSD0.
SSD1
The size of the SSD1.
Num. of CMs
The number of the cache memory.
Cache Residency
The capacity of the Cache Residency.
available size
CLPR
The CLPR number.
Cache size
The capacity of the cache memory allocated to CLPR.
Cache Residency
The capacity of the Cache Residency allocated to CLPR.
size
Extent Number
The number of extents allocated to CLPR.
Num. of CLPRs
The number of CLPR.
PP Flag
The flag of the program product.
Num. of PP Flags
The number of program product flags.
Max Number of CUs
The maximum number of CUs.
Example 4: removing a power supply
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Remove,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+DKCPS=[DKCPS-02,DKCPS-03],Num. of DKC PSs=2
Detailed information for example 4
Item
Description
DKCPS
The removed power supply.
Num. of DKC PSs
The number of power supplies.
Example 5: removing PCI
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install], Remove,SVP,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PCI ADP Equip=OFF
Install descriptions
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9500

Table of Contents