HP StorageWorks P9000 Reference Manual page 84

Audit log user and reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Detailed information for example 5
Item
PCI ADP Equip
Example 6: removing MPB
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Remove,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
{MPB,Auto LDEV Assignment}
=[{MPB-1MB,Enable},{MPB-2MD,Enable},{MPB-1MF,Enable},
{MPB-2MH,Enable}],Num. of MPBs=4
Detailed information for example 6
Item
MPB
Auto LDEV Assignment
Example 7: removing SVP
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Remove,SVP,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{SVP}={SVP-OPTION}
+{IPAddress,Subnet Mask}={(123.456.789.123),(255.255.255.255)}
+Use Duplex=Invalid
+Svp Kind=Master SVP
+IPv4=Valid
+IPv6=Valid
+{M-SVP IPv4(IPAddress,Subnet Mask),
IPv6(IPAddress,Subnet Prefix length)}
={((111.222.333.444),(255.255.255.255)),
((1111:2222:3333:4444:5555:6666:7777:8888),(64))}
+{S-SVP IPv4(IPAddress,Subnet Mask),
IPv6(IPAddress,Subnet Prefix length)}
={((555.666.777.888),(255.255.255.255)),
((9999:AAAA:BBBB:CCCC:DDDD:EEEE:FFFF:0000),(64))}
Basic information
Parameter
SVP
SVP&DKC
Detailed information for example 7
Item
SVP
IPAddress
Subnet Mask
84
Audit log examples
Description
Whether the PCI is installed or not.
ON: Installed, OFF: Not installed
Description
The installed location of the MPB.
The attribute of auto LDEV assignment.
Description
Indicates a change in the IP address of the SVP.
Indicates a change in the IP address of the SVP and the DKC.
Description
The installed location of the SVP.
IP address in the SVP.
The subnet mask in the SVP.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9500

Table of Contents