HP StorageWorks P9000 Reference Manual page 72

Audit log user and reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

Detailed information for example 1
Item
CHA
Kind
Port
Initiator/Target
Channel Speed
CU Number
Num. of Ports
HTP/FNP
Emulation
Num. of CHAs
Example 2: installing additional subsystems, ECC Groups or LDEVs
07xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,1,,
[Install],Install,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+{DKA,Kind}=[{DKA-1AL,DKF 4MP},{DKA-1LL,DKF 4MP},
{DKA-2ML,DKF 4MP},{DKA-2XL,DKF 4MP}],Num. of DKAs=4
+{DKU,Kind}=[{DKU-11,2.5" DKU}],Num. of DKUs=1
+{PG,RAID Level,Drive Type,Protection Level,Emulation,
Concatenation,Encryption}
={3-1,RAID1 (2D+2D),DKR5C-J600SS,Standard,OPEN-V,-,Disable},
++{LDKC:CU:LDEV,Emulation,Size,Unit,System Disk,SSID,MPB}
=[{0x00:0x05:0x00,OPEN-V,2251536384,LBA,Disable,0x0009,Auto}],
Num. of LDEVs=1
+{PG,RAID Level,Drive Type,Protection Level,
Emulation,Concatenation,Encryption}
={3-2,RAID5 (3D+1P),DKR5C-J600SS,Standard,OPEN-V,-,Disable},
++{LDKC:CU:LDEV,Emulation,Size,Unit,System Disk,SSID,MPB}
=[{0x00:0x05:0x01,OPEN-V,3377304576,LBA,Disable,0x0009,Auto}],
Num. of LDEVs=1
+{PG,RAID Level,Drive Type,Protection Level,
Emulation,Concatenation,Encryption}
={3-3,RAID1 (2D+2D),DKR5C-J600SS,Standard,OPEN-V,-,Disable},
++{LDKC:CU:LDEV,Emulation,Size,Unit,System Disk,SSID,MPB}
=[{0x00:0x05:0x02,OPEN-V,2251536384,LBA,Disable,0x0009,Auto}],
Num. of LDEVs=1
+Num. of PGs=3
+{B4,SPARE,Drive Type}=[{3,1,DKR5C-J600SS}],Num. of SPAREs=1
This logged information indicates that the formatting was only requested but not completed. If the
operation does not require the formatting, this logged information indicates that the volume was
created.
Basic information for example 2
Parameter
Progress Close
Quick Format
72
Audit log examples
Description
The CHA mounting location.
The kind of PCB mounted.
The mounting location of the port.
The type of Initiator or Target.
The channel speed is indicated for open systems.
1: 1 Gbps, 2: 2 Gbps, 4: 4 Gbps, 8: 8 Gbps, 10: 10 Gbps, Auto: Auto mode.
Indicates the range of the CU number that the port belongs.
The number of ports.
The HTP or FNP is indicated for FICON.
The emulation type is indicated for mainframe systems.
The number of CHAs.
Description
The progress window of the LDEV format is closed.
Quick Format was selected when an LDEV is added.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks p9500

Table of Contents