58
Warning
A disk drive or enclosure management processor (EMP) detected a serious error, such as a parity error or
disk hardware failure.
Recommended actions
If the event indicates that a disk or an expansion module is bad, replace the indicated device.
Info.
A disk drive or enclosure management processor (EMP) detected a non-serious error.
Recommended actions
No action required.
59
Warning
The controller detected a parity error while communicating with the indicated SCSI device. The error was
detected by the controller, not the disk.
Recommended actions
If the event indicates that a disk or an expansion module is bad, replace the indicated device.
Info.
The controller detected a non-parity error while communicating with the indicated SCSI device. The error
was detected by the controller, not the disk.
Recommended actions
No action required.
60
Info.
A disk channel was reset from another initiator or target.
Recommended actions
No action required.
61
Error
The controller reset the indicated disk channel to recover from a communication error. This event is logged
to identify an error trend over time.
Recommended actions
If the controller recovers, no action is required.
View other logged events to determine other action to take.
62
Warning
The indicated global or dedicated spare disk has failed.
Recommended actions
Replace the failed disk.
65
Error
An uncorrectable ECC error occurred on the buffer memory on startup. The controller is automatically
restarted and its cache data is restored from the partner controller's cache.
Recommended actions
Replace the controller module.
67
Info.
The controller has identified a new disk or group of disks that constitute a vdisk and has taken ownership
of the vdisk. This can happen when disks containing data have been inserted from another enclosure. This
event only applies to non-Active-Active controllers.
Recommended actions
You may need to clear the disks' metadata if you want to reuse them in one or more new vdisks.
HP P2000 G3 MSA System Event Descriptions Reference Guide