88
Warning
The mirrored configuration retrieved by this controller from the partner controller is corrupt. The local flash
configuration will be used instead.
Recommended actions
•
Restore the default configuration by using the restore defaults command, as described in the CLI
reference guide.
89
Warning
The mirrored configuration retrieved by this controller from the partner controller has a configuration level
that is too high for the firmware in this controller to process. The local flash configuration will be used
instead.
Recommended actions
The current controller probably has down-level firmware. Update the firmware on the down-level
•
controller. Both controllers should have the same firmware versions.
When the problem is fixed, event 20 is logged.
90
Info.
The partner controller does not have a mirrored configuration image for the current controller, so the current
controller's local flash configuration is being used. This event is expected if the other controller is new or its
configuration has been changed.
Recommended actions
•
No action required.
91
Error
In a testing environment, the diagnostic that checks hardware reset signals between controllers in
Active-Active mode failed.
Recommended actions
•
Perform failure analysis.
95
Error
Both controllers in an Active-Active configuration have the same serial number. Non-unique serial numbers
can cause system problems; for example, vdisk ownership and WWNs are determined by serial number.
Recommended actions
•
Replace one of the controller modules.
96
Info.
Pending configuration changes that take effect at startup were ignored because customer data might be
present in cache.
Recommended actions
•
If the requested configuration changes did not occur, make the changes again and then use a
user-interface command to shut down or restart the controller.
100
Info.
During Active-Active operation, an event (potential error) occurred while communicating with the enclosure
management processor (EMP).
Recommended actions
•
No action required.