472
Error
A replication failed to start on the indicated secondary volume. This can occur when the secondary system
is not licensed for replication (for example, a temporary license expired).
Recommended actions
To perform replication, ensure that the secondary system has a valid replication license.
475
Info.
A replication was queued because the indicated secondary volume is offline.
Recommended actions
No action required.
479
Error
The controller reporting this event was unable to flush data to or restore data from non-volatile memory.
This mostly likely indicates a CompactFlash failure, but it could be caused by a problem with the FPGA or
another controller component. The controller will be killed by the partner controller, who will use its own
copy of the data to perform the flush or restore operation.
Recommended actions
Look for other events, close in time, that indicate problems with the CompactFlash card.
If this event is logged more than once, replace the CompactFlash card.
480
Error
An IP address conflict was detected for the indicated iSCSI port of the storage system. The indicated IP
address is already in use.
Recommended actions
Contact your data-network administrator to help resolve the IP address conflict.
HP P2000 G3 MSA System Event Descriptions Reference Guide
41